Connect Low Pressure AOA Line
100103-01
Use the following to connect the Low Pressure AOA Line.
Applicable Aircraft Serial Numbers
00139+
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
ME000613 (LOW PRESSURE AOA LABEL)
Aircraft System and Number
10—Instruments (and Avionics)
Safety Equipment
As Needed
Consumables
None
Task Instructions
1. Identify the low pressure AOA line (routed inside fuselage on LH side of aircraft). Route to MSC.
Note: 
Do not route AOA line through fuselage wire harness tie mounts. Route the AOA line through the PITOT and STATIC cable ties.
2. Slide “LOW PRESSURE AOA” label onto the end of the tube. Trim excess hose as required and connect hose to the port on the MSC labeled “Alow”. Ensure hose is fully inserted into connector. Apply minimal heat to the heat shrink label to secure it a minimum of 1” away from the end of the tube to prevent interference with connector.
Figure 265. Connect AOA Line
Verification Method
Verify there are no instances of wire chafing and that wire protection is applied in the appropriate locations.
Verify all connectors have good connections and adequate strain relief.
Verify zip ties are tightened properly, adequately holding wire harness in place and preventing movement without visible signs of bending or cutting wire insulation/sleeving or pinching pitot/static lines.
Perform PITOT Static leak check. Pitot-Static-AOA Leak Test Procedures