G3X Instrument Panel Top Panel Removal
100514-01
Use the following procedure to remove the IP Top. This task is applicable to the Garmin G3X configuration only.
Applicable Aircraft Serial Numbers
00139+ (Applicable to the G3X Configuration Only)
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
ITL001563 (AIR VALVE INSTALLATION TOOL)
Parts Required
None
Aircraft System and Number
10—Instruments (and Avionics)
Safety Equipment
As Needed
Consumables
ICA012078 (LUBRICANT, GENERAL PURPOSE)
Isopropyl Alcohol
Task Instructions
1. Loosen air valve using installation tool ITL001563 and disconnect the air valve from RH IP top.
2. Disconnect IP top flange from the Garmin G3X Bezel clip. Disconnect LH and RH IP tops. (Figure 73)
3. Disconnect vent hose from forward side of the RH side IP top. (Figure 72)
4. Disconnect the RH side IP Top from RH crossbeam.
5. Disconnect vent hose from LH side IP Top. (Figure 71)
6. Disconnect the LH side IP Top from LH crossbeam. (Figure 70)
Verification Method
Procedure is complete when the IP Top has been removed.