ICON A5 MM : Propulsion : Engine : Fuse Box : Inspection Instructions : Inspect Regulator Wires
Inspect Regulator Wires
100267-00
Use the following procedure to inspect both Regulator A and B wires near the Regulator connectors.
Applicable Aircraft Serial Numbers
All
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
13—Propulsion
Safety Equipment
As Needed
Consumables
None
Task Instructions
1. Remove the AFT bulkhead baggage panel. (Removal and Installation of Inspection Panels and Fairings)
2. Locate the fuse box in front of the AFT bulkhead, LH as shown in Figure 414.
Figure 414. Left View of Fuselage, Fuse Box and AFT Bulkhead
3. Inspect the Regulator A and B wires near the connectors (Figure 415). Replace the Regulator if any signs of discoloration (browning) are apparent. (Remove Fuse Box and Regulators)
Figure 415. Fuse Box, Regulator A and Regulator B
Verification Method
The task is completed when both regulator wires installed do not show signs of discoloration.