Check Bilge Pump Function
100279-00
The following section includes the information necessary to check the function of the bilge pump on the
A5.
Applicable Aircraft Serial Numbers
All
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
03—Electrical System
Safety Equipment
As Needed
Consumables
None
Task Instructions
2. Turn on master switch.
3. Pour 1/2 gallon of water directly into the bottom of the hull.
4. Turn on bilge pump until no more water is pumping out.
Note:
A positive pitch attitude on the aircraft ensures optimum cleaning. This can be obtained by performing the procedure while parked on an incline (preferred), lifting the nose, or pushing down on the tail.
5. Turn bilge pump off.
6. Ensure the bilge indication has turned off.
7. Turn off master switch.
Verification Method
Verify that bilge pump successfully pumps the water from inside the hull.
Parent topic
Related references