Install Connector/Terminal
100331-00
Use the following procedure to install connector or terminal.
Applicable Aircraft Serial Numbers
All
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
Panduit CT-100A Crimper or equivalent
Parts Required
ICA011164 (Terminals FML COUPLER 16-14), As Needed
ICA011073 (Terminals FML COUPLER 22-18), As Needed
ICA011175 (TERMINAL, RTANG, PUSH ON, 10-12 AWG), As Needed
Terminals #10 12-10 RING YELLOW, As Needed
TERMINAL, RING, YELLOW, 10-12 x 1/4", As Needed
Terminals NYL-RING 12-10 YEL #8, As Needed
TERMINAL, RING, BLUE, 14-16X#10, PANDUIT, As Needed
Terminals RING 16-14 AWG 5/16, As Needed
TERMINAL, RING, RED, 18-22X#10, PANDUIT, As Needed
Terminals NYL-RING 22-18 RED 1/4, As Needed
Terminals #6 22-18 RING TERM, As Needed
TERMINAL, RING, RED, 18-22X#8, PANDUIT, As Needed
Aircraft System and Number
03—Electrical System
Safety Equipment
As Needed
Consumables
Isopropyl Alcohol (TT0I-735A or Equivalent)
Task Instructions
1. Clean connector and wire with isopropyl alcohol and let it dry before crimping.
2. Install new connector on stripped wire. Verify wire is fully seated in crimp portion of connector.
3. Crimp connector in accordance with crimper operation instructions.
4. Reconnect connector.
Verification Method
Procedure is complete when connector or terminal have been installed.