Verify Altimeter Calibration
100621-00
This section contains instructions to calibrate the altimeter for regular inspections.
Applicable Aircraft Serial Numbers
All
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
10—Instruments (and Avionics)
Safety Equipment
As Needed
Consumables
None
Task Instructions
1. Call the nearest airport and obtain altitude at the current location and barometric pressure at the time.
2. Turn master switch ON.
3. Adjust the Kollsman knob on the altimeter to match the barometric pressure.
4. Check the altimeter needle reading against current altitude to ensure it is within the allowed tolerance shown in Table 12. If the reading is outside the tolerance, contact ICON for warranty, remove and replace the altimeter. (Replace
Instrument Panel Gauges) 5. Turn Master switch OFF.
Verification Method
Ensure the altimeter reading is within tolerance at current location.
Parent topic
Related tasks