Verify Altimeter Calibration
100621-00
This section contains instructions to calibrate the altimeter for regular inspections.
Applicable Aircraft Serial Numbers
All
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
10—Instruments (and Avionics)
Safety Equipment
As Needed
Consumables
None
Task Instructions
1. Call the nearest airport and obtain altitude at the current location and barometric pressure at the time.
2. Turn master switch ON.
3. Adjust the Kollsman knob on the altimeter to match the barometric pressure.
4. Check the altimeter needle reading against current altitude to ensure it is within the allowed tolerance shown in Table 12. If the reading is outside the tolerance, contact ICON for warranty, remove and replace the altimeter. (Replace Instrument Panel Gauges)
5. Turn Master switch OFF.
Table 12. Altimeter Calibration
Altitude
Tolerance
-1,000 to 1,000 feet
±100 feet
1,000 to 10,000
±200 feet
10,000 to 20,000
±400 feet
Verification Method
Ensure the altimeter reading is within tolerance at current location.