Symptom | Possible Cause | Remedy |
---|---|---|
Battery voltage below 12.5 VDC. | Battery discharged. | Perform capacity test (1). Boost-charge battery. Charge
Battery |
Battery voltage is 0 VDC | Battery charging fuse blown. | Replace 15A fuse located forward of the positive charging terminal, on the positive charging wire. |
Battery capacity below 85% of rating (below 20.4 AH) | Battery beyond serviceable life. | |
Needs conditioning. | See the Conditioning Charge Procedure.1 | |
Battery does not hold charge. | Battery beyond serviceable | |
Battery temperature is greater than 55°C/130°F during charging. | Battery beyond serviceable life. | |
Battery voltage is 12.6 VDC or above but the battery is four years old and is not capacity tested. | N/A | Recommended to replace battery. Battery
Removal and Installation—Configuration
A |