Right Instrument Panel Top Panel Removal
100547-00
Use the following procedure to remove the right instrument panel top panel. This task is applicable to the Garmin 796 configuration only.
Applicable Aircraft Serial Numbers
All
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
T15 Torx driver
#2 right-angle crosshead driver
Eyeball Vent Tool (ITL001563)
Parts Required
None
Aircraft System and Number
05—Equipment and Furnishing
Safety Equipment
As Needed
Consumables
None
Task Instructions
3. Remove the two kneepads by carefully peeling them off. They are held on with hook and loop tape.
5. Remove the vent air hose at right side instrument panel by loosening the worm drive clamp.
6. Remove the right eyeball air valve using ICON eyeball vent tool ITL001563.
7. Remove the 6-32 screw behind the right eyeball air valve with a #2 right-angle crosshead driver. Remove the 8-32 screws at the forward-right side and at aft-left corner of the right instrument top panel with a T15 Torx driver. Remove the right instrument top panel.
Verification Method
The procedure is complete when the entire right instrument top panel has been removed.
Parent topic